Property Report

Planna Logo
Icon Image

Beechwood, Cherry Tree Lane, Chalfont St. Peter

UPRN 1.00081082947E11
Icon Image

House

186 ㎡.
Icon Image

Built in 1983-1990

Detached
Icon Image

City of GERRARDS CROSS

Local Authority
Icon Image

Official EPC Reports

House Type
Track changes to this property for Free

or Get a Free Assistant for Your Home and Property Needs

Share planna on AppstoreShare planna on Playstore

Property Maintenance Budget

* This home's yearly maintenance budget is calculated using valuation and build date data.
Move the sliding scale to update valuation and budget estimates.

Discover This Area

Planna Logo

Here are the recent sale price for homes near this property - View All Sales

CRINGLEFORD CHERRY TREE LANE, SL9 9DQ

£1.38M

Sold 14 th July 2020

BROCKWORTH CHERRY TREE LANE, SL9 9DQ

£1.42M

Sold 29 th April 2021

TWO ROOFS CHERRY TREE LANE, SL9 9DQ

£804K

Sold 07 th May 2021

Flood Risk

Flood Risk

Low
Medium
High
Crime

Crime

Burglary - 72
Bicycle Theft - 51
Other - 0
Total crimes in the area last month
123
Note: This is sample data. Please install the app for the latest data.

Get to Know This Property

Planna Logo

Running Costs

Title

Heating Costs

Current Heating Costs

£3237

Potential Heating Costs

£2730

Potential Savings

£507

Title

Hot Water Costs

Current Hot Water Costs

£552

Potential Hot Water Costs

£441

Potential Savings

£111

Title

Lighting Costs

Current Lighting Costs

£402

Potential Lighting Costs

£202

Potential Savings

£200

Energy Rating

A - G (A being the most efficient with color green, G being the least efficient with color red)

A

(92+)

B

(81 - 91)

C

(69 - 80)

D

(55 - 68)

64

Potential

E

(39 - 54)

F

(21 - 38)

G

(1 - 20)

Heating System

CO2 Emission

Average UK household produces 6 tonnes of carbon dioxide every year.

CO2 Emission

9.2

tonnes/year

Current Emissions

CO2 Emission

7.3

tonnes/year

Potential Emissions

*Estimated CO2 Emissions produced by the Property in a 12 month period.

Energy Consumption

Value is Kilowatt Hours per Square Metre (kWh/m²)

Current Estimated Total
Energy Consumption

294

kWh/m2

Estimated Potential Total
Energy Consumption

234

kWh/m2

*Estimated values for your home in a 12 month period.

Evironmental Impact Rating

A - G (A being the most environmentally friendly, G being the least environmentally friendly)

A

(92+)

B

(81 - 91)

C

(69 - 80)

D

(55 - 68)

58

Potential

E

(39 - 54)

48

Current

F

(21 - 38)

G

(1 - 20)

Recommendations

Here are EPC recommendations (get Free Report for additional recommendations):

  • Loft insulation laid in the loft space or between roof rafters to a depth of at least 270 mm will significantly reduce heat loss through the roof; this will improve levels of comfort, reduce energy use and lower fuel bills. Insulation should not be placed below any cold water storage tank, any such tank should also be insulated on its sides and top, and there should be boarding on battens over the insulation to provide safe access between the loft hatch and the cold water tank. The insulation can be installed by professional contractors but also by a capable DIY enthusiast. Loose granules may be used instead of insulation quilt; this form of loft insulation can be blown into place and can be useful where access is difficult. The loft space must have adequate ventilation to prevent dampness; seek advice about this if unsure. Further information about loft insulation and details of local contractors can be obtained from the National Insulation Association (www.nationalinsulationassociation.org.uk). - Estimated cost: NaN
  • Replacement of traditional light bulbs with energy saving recommended ones will reduce lighting costs over the lifetime of the bulb, and they last up to 12 times longer than ordinary light bulbs. Also consider selecting low energy light fittings when redecorating; contact the Lighting Association for your nearest stockist of Domestic Energy Efficient Lighting Scheme fittings. - Estimated cost: NaN
  • A condensing boiler is capable of much higher efficiencies than other types of boiler, meaning it will burn less fuel to heat this property. This improvement is most appropriate when the existing central heating boiler needs repair or replacement, but there may be exceptional circumstances making this impractical. Condensing boilers need a drain for the condensate which limits their location; remember this when considering remodelling the room containing the existing boiler even if the latter is to be retained for the time being (for example a kitchen makeover). Building Regulations apply to this work, so your local authority building control department should be informed, unless the installer is registered with a competent persons scheme{1}, and can therefore self-certify the work for Building Regulation compliance. Ask a qualified heating engineer to explain the options. - Estimated cost: NaN
  • A solar PV system is one which converts light directly into electricity via panels placed on the roof with no waste and no emissions. This electricity is used throughout the home in the same way as the electricity purchased from an energy supplier. The British Photovoltaic Association has up-to-date information on local installers who are qualified electricians and on any grant that may be available. Planning restrictions may apply in certain neighbourhoods and you should check this with the local authority. Building Regulations apply to this work, so your local authority building control department should be informed, unless the installer is appropriately qualified and registered as such with a competent persons scheme{1}, and can therefore self-certify the work for Building Regulation compliance. - Estimated cost: NaN